Platinium™ – the world's longest projected longevity.1–4

Platinium™ is an ICD with proven therapeutic functions.
PLATINIUM-DR-1540_MicroPort_front

Featuring

Parad+™

Protecting patients for over 20 years.

Featuring

BTO™

Unlocks Brady and Tachy therapies in the slow VT zone.

Featuring

SafeR™

Avoids deleterious effects of excessing RV pacing.5

 

World's longest projected longevity1–4

Platinium™ VR

  • Longevity = 14.3 years

Platinium™ DR

  • Longevity = 13.1 years

Longevity calculations are based on real life pacing conditions.6

Visit the Cardiac Device Longevity website for more information.

Backed by warranty7

Platinium™ VR

  • Warranty = 11 years

Platinium™  DR

  • Warranty = 9 years

Warranty applies regardless of pacing conditions and therapy frequency.7

Breakthrough technology that stands the test of time

  • 40% reduced electronic consumption8
  • 20% improved battery capacity8
  • Reforming-free capacitors mean zero energy is wasted

Small size

Platinium™ is designed to facilitate the implant experience and improve patient comfort.

  • Rounded edges
  • Reduced pocket size
  • Allows for smaller incision
  • Better fit for replacements
PLATINIUM-VR1240_pers_profile_measures

Ergoform™ design

Platinium™ with its smooth and curved header is designed for natural lead wrap around.

 
 

Built on proven technology

Platinium™ family is built on the heritage of MicroPort CRM technology: the PARADYM™ platform. The PARADYM™ pacemaker platform has been proven in practice.9

99.96% cumulative survival 6 years after implantation.9

Parad+™

Protecting patients for over 20 years.

  • World’s first dual-chamber discrimination algorithm
  • Best in class 99% specificity10
  • Low inappropriate shock rate5
  • Immediate protection with Parad+™ out-of-the-box setting
 
 

SafeR™

Avoids deleterious effects of excessing RV pacing.5

  • Manages all types of AV Block
  • Activated automatically on implant
  • More than 96% preserved intrinsic conduction5
 

BTO™

Unlock Brady and Tachy therapies in the slow VT zone

  • 96% specificity in slow VT zone11
  • A proof of Parad+™ discrimination performance

Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. For indications, contraindications, precautions and warnings for each devices, please refer to the product manual.

Related products:

Orchestra Plus Programmer™; Smartview Remote Monitoring System™; Vega™; Xfine™

References

  1. Medtronic – VISIA AF MRI™ VR SureScan™ DVFB1D4 Device manual M961177A001 B 2015-07-02. EVERA™ XT DR DDBB1D4 Device manual M946302A001 F 2014-03-11.
  2. (EU): Biotronik – ILIVIA™ 7 VR-T, VR-T DX, DR-T, HF-T, HF-T QP (ProMRI®) Technical Manual 417641 Revision: D (2016-08-09).
    (US): Biotronik – ILIVIA ProMRI™ Family of ICDs and CRT-Ds – Technical Manual M4206-B 01/18 / MN070 1/23/18.
  3. (EU): Saint Jude Medical – Bradycardia and Tachycardia Devices – Help Manual – June 2013 Art 60033180/A.
    (US): Saint Jude Medical – Bradycardia and Tachycardia Devices – Help Manual – November 2017 ARTEN100161329 A.
  4. (EU): Boston Scientific – Physician’s technical manual RESONATE™ HF ICD, RESONATE™ EL ICD, PERCIVA™ HF ICD, PERCIVA™ EL ICD, CHARISMA™ EL ICD, VIGILANT™ EL ICD, MOMENTUM™ EL ICD – Implantable Cardiovertor Defibrillator – 360204-001 EN Europe 2016-09.
    (US): Boston Scientific – Physician’s technical manual AUTOGEN™ EL ICD, DYNAGEN™ EL ICD, DYNAGEN™ MINI ICD, INOGEN™ EL ICD, INOGEN™ MINI ICD, ORIGEN™ EL ICD, ORIGEN™ MINI ICD, INCEPTA™ ICD, ENERGEN™ ICD, PUNCTUA™ ICD, TELIGEN™ 100 ICD – Implantable Cardiovertor Defibrillator – 359403-004 EN US 2017-04.
  5. Kolb C, et al. Reduced Risk for Inappropriate Implantable Cardioverter-Defibrillator Shocks With Dual-Chamber Therapy Compared With Single-Chamber Therapy. Results of the randomized Option study. JACC Heart Failure 2014;2:611–19.
  6. Functioning conditions for projected longevity (conditions based on MicroPort CRM data on file): DR models: Pacing in SafeR mode, 30% in atrium, 6% in ventricle, at 60 min-1, 600Ω, 2.5V, 0.35ms, 4 max shocks per year, sensor OFF. VR models: Pacing in VVI mode 6% at 40 min-1, 600Ω, 2.5V, 0.35ms, 4 max shocks per year, sensor OFF. Longevities are calculated by taking into account 6 months storage with the following conditions: Remote ON: daily check, 4 follow-ups and 5 full alert reports per year. RF telemetry ON: 45min + 15min at discharge + 15min in-clinic quarterly FU.
  7. For more details please refer to the following document supplied with the device: EU U666 – LIMITED WARRANTY for PLATINIUM ICD & CRT-D devices; US U668 – LIMITED WARRANTY for PLATINIUM ICD & CRT-D devices.
  8. Versus previous ICD generation (Paradym RF™).
  9. MicroPort CRM Product Performance Report.
  10. Hintringer F, et al. Comparison of the Specificity of Implantable Dual Chamber Defibrillator Detection Algorithms. Pacing Clin Electrophysiol. 2004;27:976–82.
  11. Sadoul N, et al. Incidence and clinical relevance of slow ventricular tachycardia in implantable cardioverter-defibrillator recipients: an international multicenter prospective study. Circulation. 2005;112:946–53.
Exemplary message

By continuing to browse this website you confirm that you are a healthcare professional.